High Efficiency 300 Ton Water Cooled Chiller Cooling Tower System

High Efficiency 300 Ton Water Cooled Chiller Cooling Tower System

High Efficiency 300 Ton Water Cooled Chiller Cooling Tower System 1. Adopt the best (semi-hermetic) screw compressor from abroad, and operate credibility, high efficiency, easy to maintain, exact volume control, a wide range of application. The system adopts the latest asymmetric rotor profile....

Chat Now

Product Details

High Efficiency 300 Ton Water Cooled Chiller Cooling Tower System


1. Adopt the best (semi-hermetic) screw compressor from abroad, and operate credibility, high efficiency, easy to maintain, exact volume control, a wide range of application. The system adopts the latest asymmetric rotor profile. Build-in pressure drop lubricant to system with low vibrations, sound emissions,high sealing performance.

2. The human machine interface configures a full touch screen, which enables automatic control and accurate monitoring. the advantages of unit: waterproof,dust-proof, corrosion resistant, long life. Step or steppless capacity control, the unit ensure that it bring into the most energy-saving effective in any load conditions.

3. Due to use heat copper tube and high efficiency compressor with high effective thermal expansion current-saving device, the unit will operate in stability, longer and effectively.

4. Chiller unit adopts a reliable safety protection device: to prevent compressor starting frequently, over-current protection, overheat of motor protection, prevent freezing, sight glass in liquid, oil heating protection, phase protection, HV/LV protection, discharge high-temperature protection, safety value, soluble clock, water shut-off protection, and so on.

5. A full intelligent control system and non-stop running within 24 hours.


High Efficiency 300 Ton Water Cooled Chiller Cooling Tower System Specifications:

Item

Specification / Supplier

Cooling capacity

Model

AYD-710WS

ton/h

300

Power input

kw

244

Max Current

A

413

Power Supply

380V-3N-50HZ

Temp   Outlet ()

7

refrigerant control

Expansion valve

Refrigeration circle

two

refrigerant

R407C

DimensionmmL*W*H

5000*900*1500

Compressor

style

Semi-hermetic Screw

Compressor power(kw)

122*2

Condenser

Style

Shell   and Tubes

Chilled water flowm3/h

227

     Pipe size(“)

8

Evaporator

Style

Shell and Tube /  1set

Cold water flowm3/h

180

Pipe size

8

Protector Device

1Phase   protector

2Fan   overload protector

3High/low   voltage protector

4Coil   overheat protector

5Anti-freeze protector

Unit Weightkg

5200

Main Parts Brand

Compressor

Hanbell

Electronic

LG    /  Carlo

Electromagnetically valve

Emerson

Expansion Valve

Emerson

PLC

Siemens

Remarks: The cooling capacity is calculated based on evaporator temp 2C,condensing temp 40C.


screw chiller parts


FAQ:

 

1.How to calculate cooling capacity for chillers

   Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86

   Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)


2. How to select the model of the chiller ?

 
  It is better to tell us some parameter, such as : Cooling Capacity, Outlet Temperature, Power Supply,Environment Temperature, Application Field, Anti-rust Or Anti-corrosion, and so on.Meanwhile,we could do customized chiller according to your end user consumption.

 

3.Cooling capacity unit conversion?

1 kcal
h 1.163W,1 W 0.8598 kcalh 
1 Btu
h 0.2931W,1 W 3.412 Btuh 
1 USRT
3.517 kW,1 kW 0.28434 USRT 
1 kcal
h 3.968 Btuh,1 Btuh 0.252 kcalh 
1 USRT
3024 kcalh,10000 kcalh 3.3069 USRT 


4. What is production period ?

   Generally speaking, it is 15-30 days,some standard model there are some stocks, but it all depend on the model ,quantity.

5.What is your company after-sales service ?

   Our warranty period is one year. If there is any problem in this year, we will send you the new parts (not including freight )for replacement. Meanwhile, welcome to consulting the technical knowledge.

 

6.Chiller HS code?

 

   8418692090

 

7.Chiller package?

 

   Wooden case

 

8.Chiller application:

Laser, Chemical, Plating and oxidation, Precision Instruments, Printing, Ink, Paper, Metal, Casting, Blowing, Injection Plastic Industry, Food Processing, Pharmaceutical Industry, Electronic Circuit Board, Wave Soldering Reflow, Interlayer Cooling, Space Purification Treatment, Ultrasonic Cleaning, Bath temperature control, Cutting and Welding, Surface Treatment, Aluminum, Glass Crafts, Jewelry Processing, Leather and Aquaculture .





ANYDA is well acknowledged as one of the leading manufacturers of high efficiency 300 ton water cooled chiller cooling tower system in China. All of the products for sale are made in our professional plant. Should you're interested in it, please be free to get the high-tech equipment with competitive price from us.
Previous:50 Ton 180 Kw Sea Water Cooled Screw Chiller R134A 440 V 60 Hz Next:Modular 100 Ton 350 Kw Air Cooled Screw Water Chiller Cooling System With Hanbell Compressor

Inquiry